Teknisk specifikationer Self-contained,
8 input 32 output unit with auto switching powersupply, will work down
to 60V mains voltage, 50/60Hz, no external power supply needed. Ergonomically designed front panel with recessed controls resulting in a ''cable and connector free'' control area. 5 segment LED meters on every input giving instant indication of input levels and or clipping. Exceptional dynamic range. Headphone ''listen'' facility, which can be expanded when usingmultiple units. DS800 Specifications Inputs 8 electronically balanced. [++] Impedance (microphone) 2k ohms. Impedance (Line) 10k ohms. CMRR >80dB @ 1kHz. Outputs FOH 8 electronically balanced. [++] MON 8 electronically balanced. [++] Isolated Feeds 16 Transformer balanced. 2.5kVAC for 1 min.isolation.( -10dB) Source Imp < 80ohms. Min. Load 600ohm. Max. Level +20dBm into 600 ohm load. Gain
10dB, 20dB, 30dB, 40dB or 50dB via 5 position switch. Headroom meter 5
point LED @ 0, -6, -12, -18, -30dB belowclipping. Frequency Resp ±0.5dB
20Hz - 20kHz. Equivalent Input Noise ( 20Hz -20kHz. Unweighted)10dB Gain: < -112dBm; 20dB Gain: < -117dBm; 30dB Gain: < -120dBm 40dB Gain: < -120dBm Distortion < 0.01% @ 1kHz, +4dB output. Power 80 to 250VAC @ 50/60Hz.Consumption < 40 watts. Weight 8.1kg. Net (9.5kg. Shipping) Size 3.5"(2U) x 19" x 12.2" (88 x 482 x 312mm) excluding connectors. Options [++] = Transformers available.
Beskrivelse The
mic/line distribution unit shall be of an active design providing 8
independent channels in a standard 2 unit, 19" rackmount enclosure.
Each channel shall provide two outputs that are actively balanced, and
accessible via rear panel XLR connectors, and two that are transformer
isolated and accessible via front panel XLR connectors. The input
shall accommodate line level signals of up to +30dBu without clipping.
Each channel shall provide gain adjustment to five settings via a front
panel switch, Mic/Line switch, 48V phantom power selectable via a front
panel switch, 5 segment LED metering and ''Listen'' facility via a front
panel switch. A -10dB pad shall be activated for each channel when 48V
power is detected on the ''Mon'' XLR connector on the rear panel.The
device shall include a headphone ''Listen'' facility via a 1 / 4 inch
phone connector with associated level control. The device shall
provide facility to link the ''Listen'' busses together when using
multiple devices. The device shall be powered from an internal power
supply, which will operate from an 80-250V 50/60Hz power supply. The
mic/line distribution unit shall be the XTA Electronics DS800.